Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

Determining the volatile matter content in shielding plates is a critical quality control process for ensuring material stability and performance in electronic applications. This technical article outlines the standard testing methods, sample preparation techniques, and industry standards used to accurately measure volatile components in shielding materials.

Technical Overview

Shielding plates are essential components used in electronic devices to suppress electromagnetic interference (EMI). These materials often consist of metal alloys, conductive coatings, or composite structures containing polymers and adhesives. The determination of volatile matter content is a vital test to assess the thermal stability and environmental suitability of these materials. Volatile matter generally refers to moisture, residual solvents, plasticizers, and other low-molecular-weight organic compounds that evaporate when exposed to elevated temperatures.

Excessive volatile content can lead to significant reliability issues in electronic assemblies. During operation, heat generated by components can cause these volatiles to outgas. This outgassing can lead to the formation of bubbles, delamination of shielding layers, or the deposition of condensates on optical surfaces and sensitive circuitry. Therefore, precise measurement of this parameter is strictly required by material specifications and industry standards.

Testing Samples

Metal Based Shielding Plates

These samples typically consist of stamped metal sheets (such as copper, aluminum, or steel) often coated with an insulating layer or adhesive. The testing focuses on the volatile components within the surface treatments, adhesives, or any polymeric films laminated onto the metal substrate. Samples must be cleaned to remove surface oils before testing to avoid skewing results.

Conductive Polymer Composites

These shielding materials incorporate conductive fillers (like carbon black, graphite, or metal fibers) into a polymer matrix. The potential for volatile release is higher in these materials due to the resin content. Samples are usually taken from the core of the material to ensure representativeness, avoiding surface contamination.

Adhesive Tapes and Films

Many shielding plates are attached using conductive adhesive tapes. These adhesives are prone to solvent retention. Testing involves isolating the adhesive layer or testing the composite tape structure to determine the total weight loss upon heating.

Testing Items

The primary objective is to quantify the mass loss of the shielding plate material when subjected to specific thermal conditions. Key testing items include:

  • Total Volatile Matter Content: The total percentage of mass lost due to heating.
  • Moisture Content: Specifically quantifying water vapor loss, often distinct from organic volatiles.
  • Thermal Weight Loss: Measuring stability across a temperature gradient.
  • Outgassing Potential: Qualitative or quantitative analysis of released gases.

Testing Methods

The industry standard approach for determining volatile matter content is the Gravimetric Method. This method relies on measuring the mass of a sample before and after a controlled heating process using a precision analytical balance. The procedures typically adhere to standards such as GB/T 2915, ASTM D1209, or specific customer specifications.

Sample Preparation

Specimens are cut to a specific size, typically ensuring a sufficient surface area to volume ratio for efficient volatilization. The sample is weighed to the nearest 0.0001g to establish the initial mass ($M_1$). A minimum of three specimens is usually tested to ensure statistical validity.

Heating Procedure

The prepared sample is placed in a pre-heated drying oven or muffle furnace. The temperature and duration are strictly defined by the material specification. Common conditions for shielding materials range from 105°C for moisture determination to 150°C–200°C for total volatile matter, with durations lasting from 30 minutes to several hours. The temperature must be uniform throughout the working chamber.

Cooling and Weighing

After the heating cycle, the sample is transferred to a desiccator to cool to room temperature in a dry environment. This prevents the re-absorption of atmospheric moisture, which would invalidate the test results. Once cooled, the final mass ($M_2$) is recorded.

Calculation

The volatile matter content is calculated using the mass difference. The formula is expressed as:

Volatile Matter (%) = [(M1 - M2) / M1] x 100%

Accredited third-party laboratories ensure accuracy by using calibrated balances and validated oven temperature profiles. In some advanced cases, Thermogravimetric Analysis (TGA) is utilized to provide a continuous profile of weight loss as a function of temperature.

Applications

The control of volatile matter in shielding plates is critical across various high-tech sectors:

  • Mobile Devices: In smartphones and tablets, compact designs trap heat, making low volatile content essential to prevent screen fogging and component corrosion.
  • Automotive Electronics: Electronic Control Units (ECUs) and sensors operate in high-temperature environments; stable shielding materials are necessary to prevent outgassing that could foul sensors.
  • Telecommunications: Base stations and server hardware require long-term reliability where material degradation due to volatile release must be minimized.
  • Aerospace: In vacuum or low-pressure environments, volatile outgassing can contaminate optical instruments, making strict volatile control mandatory.

FAQ

What is the acceptable limit for volatile matter in shielding plates?

Acceptable limits vary depending on the application and the specific material formulation. However, for high-performance electronics, volatile content is typically required to be less than 1.0% or even 0.5%. Customer specifications usually define the exact threshold.

How does sample thickness affect the test results?

Thicker samples may retain volatiles longer than thin films due to diffusion barriers. Standards often specify maximum sample thickness or require samples to be cut into small pieces to facilitate the release of volatiles during the heating phase.

Why is cooling in a desiccator important?

Cooling in a desiccator is crucial because a hot sample can rapidly absorb moisture from the ambient air as it cools. This absorbed moisture would increase the final weight, leading to an artificially low calculation of volatile matter content.

Is TGA better than the oven method?

Thermogravimetric Analysis (TGA) provides more detailed information, such as decomposition temperatures and multi-stage weight loss, but it handles much smaller sample sizes. The conventional oven method is often preferred for quality control due to its lower cost, simplicity, and ability to test larger, more representative samples.